Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre (ILC) is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILC for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.



Item Details

Apex DynaFlo 8000 Static and Alternating Air Mattress System

ILC Reference NO 21:14:047
Item sourced from ILC QLD database


Apex DynaFlo 8000

Short Description
A mattress system which consists of a replacement mattress and an electrically operated pump. The mattress provides alternating air pressure as well as a static air mode. The static mode allows care tasks to be performed without interference from mattress surface changes. The pump unit has LED indicators and an alarm which warns when the pressure becomes too low. The cell-in-cell design of the mattress ensures a nominal support is provided to the user in the case of the pump not working due to a power failure. The mattress has a CPR release valve and a water resistant cover which is vapour permeable for air circulation. Suitable for users who are at high risk of developing pressure sores. Available in a single size.

More Details
MATERIALS: Air cells: nylon laminated with PVC/P.U. and have a vinyl cover.
Cover: a combination of nylon/P.U. and nylon/polyester cotton.

FEATURES: . Cell-in-Cell design - ensures the user is provided with support in the case of a power failure when the pump is unable to supply air pressure.
. Low air loss lasered air cells.
. CPC Quick Connectors - for easy connection and disconnection which simplifies the mattress set-up process.
. Spring loaded tubes - which prevents kinking or bending and ensures the best air flow to the mattress.
. An over-sized carry bag is provided standard to allow the entire unit to be carried and transported with ease.

COVER: The mattress cover is water resistant for protection of the mattress. The cover is also vapour permeable providing air circulation around the user. It is of a non shearing style and has extra quilting for comfort. The cover has a zipper all around to enclose the mattress fully and allow removal and cleaning when required. A pair of feet are printed on the cover to assist with mattress orientation.

COMPONENTS: There are 20 air cells which are blue in colour and are of a non shearing style:
- 2 no air loss, non alternating for under the pillow (to minimise air circulation around the face)
- 1 with air loss, non alternating for under the pillow
- 10 low air loss and alternating with micro lasered holes for under the trunk
- 7 no air loss and alternating for under the legs and feet.

OPERATION: Inflation:
When the switch is turned on, the microchip processor will cause the motor to quickly inflate all cells. The correct inner pressure of all cells can be reached quickly. When inflated, a user dialled pressure setting is entered. The microchip will automatically adjust pressure according to this setting. Once the correct inner pressure is reached, the microchip processor will then switch to alternating mode and suspend the internal compressor pump operation. This increases the life of the compressor and reduces power consumption. The compressor pump will come back on when the air pressure is decreasing below the selected setting.

Static Mode:
With the push of a button (blue switch) the alternating function ceases and the low preset pressure is redistributed across all cells within the mattress. The static mode allows tasks to be performed without the interference from mattress surface changes. The static mode can be changed back to the alternating mode by pushing the same button.

COMMENTS: . Suitable for bed sore treatment Stage II and III.
. Pump is fixed via a two piece arm style stand which attaches to the bed.

SAFETY: . There are two LED indicators which verify the pressure status of the mattress. An amber light indicates when the pressure is low both during initial inflation and when the normal pressure is decreasing below 5mmHg. The green light indicates the inner pressure is normal. An audible alarm sounds to warn users and carers when the inner pressure of the cells is below 5mmHg.
. The mattress has two CPR valves which are designed for quick release of air from the cells when there is an urgent need to perform CPR on the user (pull the yellow tags).
. Slip resistant mats - the bottom of the mattress comes with slip resistant mats to prevent slide movement of the mattress and provide better safety and stability.


Models
One model is available.


Dimensions
Apex DynaFlo 8000 Mattress
Overall Width..................................... 910 mm
Overall Depth..................................... 200 mm, inflated
Overall Length.................................... 2300 mm


Place Of Manufacture
Taiwan

Warranty
Unknown, please contact supplier for details.


Display Item On Loan From
Townsville Display Centre:
Not on display.
Brisbane Display Centre:
Not on display.
Please be aware that this device may be available upon request for an individual consultation. A general consultation fee may be required for this service. Please contact LifeTec Queensland for more details.


Standards
For some types of equipment, specific Australian or other Standards are applicable to the materials used in, and the manufacturing and installation of products. Compliance with relevant Standards is indicated by written certification that a product has been tested and assessed as compliant with specified Australian Standards. Purchasers are advised to check with the supplier or manufacturer of an item as to its compliance with the relevant Standard(s).


Price Guide
Refer to supplier details for pricing.

Supplier Information - click to supplier for contacts details
ELAN MEDICAL SUPPLIES - BEENLEIGH OFFICE,   BEENLEIGH, QLD
SSS AUSTRALIA,   MURARRIE, QLD

Additional /images
.   Carry Bag  
Click Thumbnail to view larger image.

First   Prev Previous page  Next page Next   Last

page spacer