Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre (ILC) is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILC for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.



Item Details

Bariselect Low Air Loss Mattress

ILC Reference NO 21:14:032
Item sourced from ILC NSW database


Bariselect Mattress

Short Description
A low air loss mattress replacement system consisting of a 16 cell mattress and control unit. Includes pulsation and features to preset the pressure to the patients weight. An optional hand held control is available for patient use. A foot pillow prevents slipping down the bed. The load capacity is 308.7kg. Suitable for bariatric use. Custom sizes are available.

Price Guide
Approx Price: $8,950.00
Price Date: 17/08/2007
Prices from Seating Dynamics
$8950 900mm, 1000mm
$9950 1200mm, 1300mm & 1500mm


More Details
STRUCTURE
16 individual cells (baffles) divided into three sections: head, seat and foot. Integrated side air bolsters with foot pillow. Air circulates through the cells and escapes from 33 air openings distributed equally across the top mattress surface. It circulates under a vapour permeable cover to wick moisture away from the patient.
A Foot Pillow prevents skin breakdown due to patient slipping down the bed.

COVER
Waterproof, vapour permeable (breathable), zippered mattress cover

ATTACHMENT
Four straps are located on each side of the mattress cover. These are for strapping to the bed frame.

ADDITIONAL FEATURES

Upright Patient Mode
Provides added support when the bed head is elevated. Patient can sit upright without bottoming out.

Firm Mattress Mode
Helps facilitate nursing care during dressing changes and patient repositioning.

System Lock
Prevents accidental adjustments and automatically resets the system in case of power failure

Auto Comfort
During set up, mattress sets optimal pressure according to patient's weight distribution.

Pulsation
Provides three cycle settings that continually readjust the system to ensure patient comfort.

APPLICATION
The manufacturer states that all SelectAir mattresses can be used on patients with any stage ischaemic (pressure) ulcer, myocutaneous skin flaps, skin grafts and/or patients with temperature, moisture control or pain management issues.

SAFETY
In case of emergency, turn the power off. Deflation will be aided by removing the hose from the mattress or control unit.

CLEANING
Follow manufacturer's instructions for disinfecting the mattress.

CONTROL UNIT (AIR PUMP)
Quiet motor
Rapid inflation
Quick change filter (see manufacturer's instructions)
Voltage 120V AC 50/60 Hz
Current less than 5 amps


Models
One model is available in single bed size

Options
Handheld control

Factors To Consider
All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (eg correct inflation levels), a different product may need to be considered.


Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For a fact sheet about standards contact us or visit www.ilcaustralia.org/home/standards.asp

Place Of Manufacture
USA


Dimensions
Mattress
Load Capacity (supplier stated) NSW............... 308.7 kg
Weight (kg) NSW................................... 6.8 kg (based on 1200mm wide mattress)
Length NSW........................................ 2000 or 2100 mm (2100mm with foot pillow)
Height NSW........................................ 250 mm
Width NSW......................................... 900, 1000, 1200, 1300 or 1500 mm


Additional Dimensions
Compressor
Weight (kg) NSW................................... 4 kg
Length NSW........................................ Unknown
Height NSW........................................ Unknown
Width NSW......................................... Unknown


Supplier Information - click to supplier for contacts details
ACTIVE MOBILITY SYSTEMS,   LIDCOMBE, NSW
ACUTE HEALTHCARE,   SEVEN HILLS, NSW
MOBILITY 2 YOU,   ERINA, NSW
SDL (SEATING DYNAMICS PTY LTD),   SEVEN HILLS, NSW

Additional /images
No additional /images apply to this item

First   Prev Previous page  Next page Next   Last

page spacer