Whilst all care is taken to provide accurate information with respect to the item described, the Independent Living Centre (ILC) is not involved in product design or manufacture, and therefore not in a position to guarantee the accuracy of the information provided. Selection of equipment, which is both suitable and appropriate for individual needs remains the responsibility of the person(s) considering requisition, and no responsibility is taken by the ILC for any loss or injury caused through use of the equipment or alleged to have arisen through reliance upon information provided. As information is subject to change any enquiries should be directed to the manufacturer.



Item Details

Apex Neopro 8000 Mattress Replacement System

ILC Reference NO 21:14:082
Item sourced from ILC NSW database


Neopro 8000 Mattress

Short Description
A mains powered, electrically operated alternating air mattress replacement designed for pressure reduction in high and very high risk users or those with existing pressure ulcers up to stage four. It has a two way stretch, water resistant and vapour permeable (breathable) cover, which is removable. Available in single bed size only.


Price Guide
Approx Price: $3,964.00
Price Date: 01/08/2007
$3500 Neopro 8000 (includes pump and mattress)


More Details
The system consists of a portable pump unit and mattress made from nylon, laminated with polyurethane. A separate mattress cover completes the system.

The mattress features individual cylindrical air cells that span the full width of the mattress. The cells press stud into place and are separate from the base and each other so that they can be removed and replaced if punctured.

The pump supplies air to each alternate cells resulting in a cycle of alternating inflation and deflation. There are four choices for the length of the cycle. The three air cells at the head end remain at a constant pressure to minimise the sensation of movement for the user. The cells in the main trunk area feature low air loss, designed to improve air circulation around the user and reduce perspiration. A seat inflate function increases the mattress pressure when the user is sat up in bed. A static mode of inflation is also present.


FEATURES

COVER a separate, water resistant cover with two way stretch is provided. This cover is breathable (vapour permeable) and has microbial properties. It covers the entire mattress and attaches with a zipper.

STRUCTURE consists of 20 deep air cells. Individual air cells can be removed if punctured, for repair or replacement. There are 11 low air loss cells in the main trunk area which are designed to maximise air circulation around the client and minimise perspiration. A cell within cell design allows quick inflation/deflation and provides additional support in case of power failure, remaining inflated when the pump is unable to supply air pressure.

ATTACHMENT is via securing straps with hook and loop fastening, which can be secured underneath the existing mattress or underneath the mattress overlay. The base of the mattress cover also has slip resistant qualities.

PUMP / CONTROLS a separate, portable alternating pressure pump features digital control of cycle time, pressure range, panel lock to prevent accidental changes to settings, autofirm (for quick inflation at set up), static mode and seat inflate. There is a written guide on back of the pump for reference. The pump has a bracket attachment to enable it to be hung on the bed frame if desired. Air hoses are covered with a nylon cover to prevent accumulation of dust. The air hoses have spring loaded CPC connectors which minimise accidental disconnection and are spring loaded, preventing kinks or bending.

SAFETY FEATURES The pump features a low pressure warning signal, which is audible and visible, and indicates pressures 5mmHg less than set pressure. The overlay has an emergency CPR release handle, which allows rapid deflation of the mattress for cardiopulmonary resuscitation. An intubation facility allows rapid deflation of the top four cells enabling access for this procedure.

CLEANING REQUIREMENTS Wipe clean with non phenyl based cleaner.

MAINTENANCE
Check the mattress replacement daily for punctures or air loss.


Models
Neopro 8000 AX.PM4800

Method Of Use
METHOD OF OPERATION
1. Place the mattress on the bed and inflate until it feels firm, with minimal give when pressed.
2. Position the user on the mattress
3. Place one hand under the user, where the mattress is most compressed (ie under bony prominences of the bottom / pelvis).
4. Choose an air cell which is in the compressed cycle.
5. Turn your hand so it is facing sideways and slide your fingers along the cell.
6. If you are unable to slide a hand under the user the pump output will need to be increased. If there is excessive space between the user and the base of the mattress the pump output will need to be reduced.



Factors To Consider
All pressure reduction products must be monitored to prevent 'bottoming out'. This occurs when the user's weight bears down so hard on the product material that it is flattened and the bony parts are pressed against the surface below the cushion or mattress. Where bottoming out occurs even with correct use (eg correct inflation levels), a different product may need to be considered.

Standards
Some assistive technology needs to meet Australian or other standards. Standards may relate to materials, manufacturing and installation. Products that meet Australian or international standards will have written certification. To find out if a product meets Australian Standards ask the supplier to show you the certificate. For a fact sheet about standards contact us or visit www.ilcaustralia.org/home/standards.asp

Place Of Manufacture
Taiwan

Dimensions
Mattress
Load Capacity (supplier stated) NSW............... 180 kg
Weight (kg) NSW................................... 6 kg
Length NSW........................................ 2000 mm
Height NSW........................................ 230 mm
Width NSW......................................... 900 mm


Additional Dimensions
Compressor
Weight (kg) NSW................................... Unknown
Length NSW........................................ Unknown
Height NSW........................................ Unknown
Width NSW......................................... Unknown


Supplier Information - click to supplier for contacts details
GMS REHABILITATION (IMPORTER),   TRARALGON, VIC

Additional /images
Neopro Mattress Controls  
Click Thumbnail to view larger image.

First   Prev Previous page  Next page Next   Last

page spacer